Logo Bremen Barrierefrei

Bremen accessible

Criteria for rough guidance

What do the arrows mean?

The coloured arrows and pieces of information provided are the first navigation aids. Read all the measures and information for more detail. If none of the predefined measures are met, the destination is assigned a red arrow. Establishments that have more than 2 steps are only highlighted if they are especially important.

Entrance accessibility

fully accessible
generally accessible
limited accessibility
poor accessibility

Filtering features for the initial overview

  accessible generally limited
Entrance
Doorway width [cm]≥ 90≥ 80≥ 70
Open space in front of and behind doors [width x depth; cm],
including in the vestibule
≥ 150 x 150≥ 120 x 120also lower
Height of slopes/steps [cm]0≤ 3≤ 17
Sets of steps (height ≤ 17 cm)00≤ 1
Incline of ramp at the entrance (≤ 2 m length) [%] ≤ 6≤ 10≤ 16
If both doors can be opened easily from a seated position (door handle height at a max. 1.40m, strength required ≤ 3kp),
the entire doorway width is entered.

Usability of rooms

fully accessible and usable
generally usable
limited usability
difficult to use
  accessible generally limited
General accessibility (assessed for every room)
Narrowest door/passageway [cm] ≥ 90≥ 80≥ 70
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Height of slopes/steps [cm]0≤ 3≤ 17
Sets of steps (height ≤ 17 cm)00≤ 1
Incline of ramp at the entrance (≤ 2 m length) [%] ≤ 6≤ 10≤ 16
If both doors can be opened easily from a seated position (door handle height at a max. 1.40m, strength required ≤ 3kp),
the entire doorway width is entered.
Bars/counters and kitchens
Bar height [cm]≤ 85≤ 105≤ 105
Open space in front of the bar [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Rooms with fixed seating (such as theatres or churches)
General accessibility, see above
Narrowest passageway in the room [cm]≥ 90≥ 80≥ 70
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Space for wheelchair users if approached directly
[width x depth; cm]
≥ 90 x 130≥ 80 x 120≥ 70 x 100
Space for wheelchair users if approached from the side
[width x depth; cm]
≥ 90 x 150≥ 80 x 120≥ 70 x 100
Open space around the location if approached directly
[width x depth; cm]
≥ 150 x 150≥ 120 x 120≥ 100 x 100
Open space around the location if approached from the side
[width x depth; cm]
≥ 90 x 150≥ 80 x 120≥ 70 x 100
Rooms with movable seating (such as seminar rooms or guest rooms)
General accessibility, see above
Arrowest passageway in the room, as it is currently used [cm] ≥ 90≥ 80≥ 70
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Bar height [cm]
(Nur bei Selbstbedienung im Gastraum)
≤ 85≤ 105≤ 105
Variant 1: Room with tables and chairs,
and at least one place with a height that a wheelchair can fit below ≤ 85 cm.
Wheelchair-compatible depth ≥ 30 cm,
open space in front ≥ 120 cm (depth.)
fulfilledfulfilled 
Variant 2: Room with tables and chairs,
at least one place that can easily be accessed
by standard wheelchairs (either directly or from the side).
  fulfilled
Variant 3: Room with chairs only,
and at least one space for standard wheelchairs
fulfilledfulfilled 
WC
General accessibility, see above
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Narrowest passageway in the room [cm]≥ 90≥ 80≥ 70
Open space in front of the WC [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Space to the left or right of the WC (width) [cm]≥ 90≥ 80 
Hinged handrail or transfer handhold, mounted above the WC
or hanging handrail
on both sides on at least
one side
on at least one side:
Hinged handrail or
fixed handle
Height of WC seat [cm]46 - 48not specifiednot specified
Door opens outwardsyesyes 
Children's WC
General accessibility, see above
Open space in front of and behind doors [cm]≥150 x 150≥120 x 120≥100 x 100
Narrowest passageway in the room [cm]≥90≥80≥70
Open space in front of the WC/changing table [cm]≥150 x 150≥120 x 120≥100 x 100
(Die geringere freie Fläche ist entscheidend)
Hotel room with bath and WC
General accessibility, see above
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Narrowest passageway in the room [cm]≥ 90≥ 80≥ 70
Open space in the room [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Open space to the right or left, next to the bed,
at a depth of at least 1.50 m
≥ 90≥ 80≥ 70
Height of mattress, top edge of the bed [cm]maximal 50  
Narrowest passageway to the WC [cm]≥ 90≥ 80≥ 70
Bath/WC
Narrowest passageway in the room [cm]≥ 90≥ 80≥ 70
Open space in the room [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Width of entrance to the shower [cm]≥ 90≥ 80≥ 70
Shower tray area [cm]150 x 150120 x 120100 x 100
Shower threshold [cm]on grade≤ 3≤ 3
WCsee WCsee WCsee WC
Treatment room
General accessibility, see above
Open space in front of and behind doors [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Narrowest passageway in the room [cm]≥ 90≥ 80≥ 70
Open space in the room [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Open space in front of or next to the treatment chair/couch [cm] ≥ 150 x 150≥ 120 x 120≥ 100 x 100
Height adjustable treatment chair/couchfulfilledfulfilled 
Lowest height of treatment chair/couch [cm] ≤ 40  
Foldable armsfulfilledfulfilled 
Width of treatment couch [cm]≥ 100≥ 80≥ 60
Other rooms (e.g. exhibition room, trade fair hall)
General accessibility, see above
Arrowest passageway in the room, as it is currently used [cm] ≥ 90≥ 80≥ 70
ATM (cash machine)
Open space in front of the ATM [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Input/output height [cm]≤ 85≤ 95≤ 105
Depth of input area [cm]≤ 20≤ 30≤ 40
Screen information is easy to read from a seated positionfulfilledfulfilled 
Operation exclusively using PIN keypadfulfilledfulfilled 
Railway platform
General accessibility, see above
Narrowest door/passageway [cm]≥ 140≥ 130≥ 120
Freie Fläche auf dem Bahnsteig [cm]≥ 150 x 150≥ 120 x 120≥ 100 x 100
Can entire length of railway platform be used by a wheelchair userfulfilledfulfilled 

Obstacles

Information about obstacles is included in the room assessment.

  accessible generally limited
Lift
Doorway width [cm]≥ 90≥ 80≥ 70
Open space in front of the lift [cm]≥ 150 x 150≥ 120 x 120less
Cabin depth [cm]≥ 140≥ 125≥ 100
Cabin size when cabin is exited from the side [cm]≥ 140 x 140≥ 140 x 140≥ 125 x 125
Platform lift
Entrance width [cm]≥ 90≥ 80≥ 70
Open space in front of the platform lift [cm]≥ 150 x 150≥ 120 x 120also lower
Platform can be operated by userfulfilledfulfilled 
Platform dimensions [cm]≥ 90 x 140≥ 90 x 140≥ 80 x 100
Platform dimensions if accessed from the side [cm]≥ 120 x 140≥ 100 x 140≥ 90 x 100
Ramp
Narrowest door/passageway [cm]≥ 90≥ 80≥ 70
Incline [%]≤ 6≤ 6≤ 10
Longest section [m]6610

Some of the arrows are assigned automatically. Differences of -5% are permitted for the space for movement. Differences of -1.5% are permitted for doorway widths/passageway widths.

Do you have any questions that have not yet been answered? Then please contact the particular establishment directly.